CFYPJ - CALIBRATION GAS, PROPANE 525 PPM IN AIR

  • MSDS: CFYPJ
  • Manufacturer: BACHARACH INC
  • Product Name: CALIBRATION GAS, PROPANE 525 PPM IN AIR
  • National Stock Number: 6665-01-143-4583
Product Identification

Product ID:CALIBRATION GAS, PROPANE 525 PPM IN AIR
MSDS Date:12/08/1994
FSC:6665
NIIN:01-143-4583
MSDS Number: CFYPJ

Responsible Party
BACHARACH INC
625 ALPHA DRIVE
PITTSBURG, PA 15238
US

Emergency Phone: 412-963-2000/800-424-9300(CHEMTREC)

Info Phone: 412-963-2000

Cage: 05083

Contractor
BACHARACH INC
PITTSBURGH, PA 15238 US

Telephone: 412-963-2130

Cage: 05083

Ingredients

PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 0.05%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9596


AIR

Fraction By Weight: 99.95%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: WHILE PROPANE IS A SIMPLE
ASPHYXIANT, THIS MIXTURE CONTAINS SUCH A SMALL AMOUNT THAT IT IS
PRACTICALLY NON-TOXIC. CHRONIC: NONE KNOWN/EXPECTED.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE KNOWN OR EXPECTED.

First Aid

First Aid:NONE NORMALLY REQUIRED.

Fire Fighting

Flash Point Method:CC
Flash Point:-155F,-104C
Autoignition Temp:Autoignition Temp Text:450C
Lower Limits:2.1
Upper Limits:9.5
Extinguishing Media:THE GAS IN CYLINDER IS NOT FLAMMABLE (FLASH IS FOR
PROPANE-<1% OF GAS IN CYLINDER).
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL FIRE FIGHTER'S PROTECTIVE GEAR. USE WATER TO COOL FIRE EXPOSED
CONTAINERS.
Unusual Fire/Explosion Hazard:THIS MIXTURE IS BELOW LEL OF PROPANE & IS
NON-FLAMMABLE. COMPRESSED AIR/PROPANE MIXTURES CAN ACCELERATE
BURNING OF OTHER MATERIALS. HEATED CYLINDERS MAY VENT.

Accidental Release

Spill Release Procedures:NONE NEEDED. THIS MATERIAL IS NON-TOXIC &
NON-FLAMMABLE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE NEAR HEAT OR OPEN FLAME.
STORE BELOW 130F. SECURE CYLINDERS-DO NOT DROP. WHEN REMOVABLE CAP
GIVER, STORE & HANDLE WITH CAP IN PLACE.
Other Precautions:DO NOT PUNCTURE. NEVER THROW CYLINDER INTO FIRE OR
INCINERATOR. DO NOT DROP OR DAMAGE. USE ONLY WITH PROPER EQUIPMENT
OF PROPER PRESSURE RATING. DO NOT TAMPER WITH PRESSURE RELIEF
VALVE. CLOSE CYLINDE R VALVE WHEN CYLINDER NOT IN USE.

Exposure Controls

Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:NO SPECIAL REQUIREMENTS.
Protective Gloves:LEATHER FOR HANDLING CYLINDERS.
Eye Protection:SAFETY GLASSES RECOMMENDED.
Other Protective Equipment:NONE NORMALLY REQUIRED.
Work Hygienic Practices:USE NORMAL GOOD HYGIENE PRACTICES.
Supplemental Safety and Health
NOTE: ALL PHYSICAL PROPERTIES DATA & FLASHPOINT/AUTOIGNITION DATA IS
FOR PROAPNE, NOT (!!!) THE MIXTURE. END ITEM DESCRIPTION: NSN
6665-01-142-9106 GAS ALARM.

Chemical Properties

HCC:G3
Boiling Pt:B.P. Text:-44F,-42C
Melt/Freeze Pt:M.P/F.P Text:-306F,-188C
Vapor Pres:GAS
Vapor Density:>1.0
Spec Gravity:>1.0
Evaporation Rate & Reference:NONE SPECIFIED BY MFR.
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS, TASTELESS GAS IN CYLINDERS. NO
DATA AVAILABLE.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Hazardous Decomposition Products:NONE KNOWN.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DO NOT INCINERATE CYLINDER. DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.